Color Fastness to light (ISO 105-B02 & M&S C9)


Step: 1- Precaution /Condition Taking before testing.

Receiving samples are required minimum 6 hours condition with temperature @ 20±2 °C & humidity 65±2 °C.

                    APPARATUS REQUIRED

20280500-FILT OUT CIRA ON SODALIME

20909900-AUXILARY FILTER LANTERN WITH  INSULATER 

20200700-FILTER ,FLOAT GLASS , Ci3000(6NOS)

07480200-SPECIMEN HOLDER
QUARTZ (INNER FILTER)

BRITISH BLUE WOOL STD.FROM STD 1 TO 8
WHITE CARD FREE OPTICAL BRIGHTING AGENT

Step: 2 Set the Machine as per ISO, M&S and AATCC Test procedure
             
                 ISO TEST PROCEDURE
INNER FILTER (BOROSILICATE)
OUTER FILTER (SIRA-ON SODALIME)
XENON ARC LAMP
FLOAT GLASS(6 NOS)
               FOR M&S TEST METHODE

INNER FILTER (QUARTZ)
OUTER FILTER (SODALIME)
XENON ARC LAMP

              FOR AATCC TEST METHODE
XENON ARC LAMP
INNER FILTER
OUTER FILTER
Step: 3 Set the Machine as per required lamp and filter.

Step: 4 Run the Machine as per customer required protocol and faded the British blue wool as per customer required protocol.

Step: 5 Grade the sample against the blue wool and compare the faded of the blue wool and specimen.